100 - 240V Power Supply for A72x, A73x, A75x
This switch mode power supply typically delivers a 6W output and features a wide range input (100-240V), while maintaining small size and light weight.
Output power is fixed with a tolerance of + 3% to 9V DC at 300mA to prevent excessive power input on your ADCON RTU (must not exceed 10VDC at power port). Primary connection is to a standard wall outlet (see below for details), while the secondary cable connection to your ADCON RTU is provided through a 6m cable, featuring a 5-pin M9 Binder connector, as matches all power connectors on AdDCON RTUs (except A740 addNODE).
The primary connector of this unit is a two-pole Type C connector, according to the European standard CEE 7/16. It will fit all European standard domestic power sockets, except those according to the BS1363 system (Type G), which are used in Great Britain, Ireland, Cyprus, Gibraltar, and Malta. For other countries (UK, US, Australia) see tab "Ordering" and check under related articles.
This unit is not meant for unprotected outdoor use!
Request a quote or advice
Output power is fixed with a tolerance of + 3% to 9V DC at 300mA to prevent excessive power input on your ADCON RTU (must not exceed 10VDC at power port). Primary connection is to a standard wall outlet (see below for details), while the secondary cable connection to your ADCON RTU is provided through a 6m cable, featuring a 5-pin M9 Binder connector, as matches all power connectors on AdDCON RTUs (except A740 addNODE).
The primary connector of this unit is a two-pole Type C connector, according to the European standard CEE 7/16. It will fit all European standard domestic power sockets, except those according to the BS1363 system (Type G), which are used in Great Britain, Ireland, Cyprus, Gibraltar, and Malta. For other countries (UK, US, Australia) see tab "Ordering" and check under related articles.
This unit is not meant for unprotected outdoor use!
Approvals
EU/UK
Approvals
US
Test Standards:
- EN 60950
- UL 1310
- EN 61000-6-1
- EN 55022
- EN 55011
- EN 55014-1
- EN 61204-3
Download PDF
Download PDF
Dimensions in mm | 95 x 42 x 29,5 LxBxH |
Input Parameters: | |
Voltage in VAC | 100 ... 264 |
Current in mA | 3 ... 175; typ. 145 |
Frequency in Hz | 47 ... 63; typ. 50 |
Efficiency in % | 65 ... 80 |
Operating temperature | -5°C ... +40°C |
Output parameters: | |
Voltage in VDC | 8 ... 9; typ. 9 |
Voltage tolerance | 3% |
Current | max. 300mA |
Ripple voltage | max. 50mV |
Cable length | 5m |
Connector secondary | Binder M9 m 5-polig |
Connector primary | Depending on country specifics: Europe: Type C, CEE 7/16 Australia: Type I AS3112 UK: Type G USA: Type A |